显示标签为“mini dc pump”的博文。显示所有博文
显示标签为“mini dc pump”的博文。显示所有博文

2016年7月10日星期日

The common faults and reasons of mini dc pump system

The common faults and reasons of mini dc pump system
Leaking water,please check the leaking parts
---fastening pump head nut or replace the sealing ring of outer sleeve.
---the mechanical seal has quality problem,please replace it.
The noise of mini pump
---there is foreign matter in the pump,please remove it.
---the flow movement,please turn down valve.

The noise of motor
---the motor is shortage of oil,please filling grease.
---replace the motor bearing.
---Motor overload,turn down the outlet valve of brushless dc pump.

The lift and flow can’t meet the requirements
---there is air in the pump,please exhaust the air.
---the inlet or outlet of pump is blocked,please clear debris.